Release Notes for ProLiant Support Pack for Microsoft Windows Server 2003, v7.60 Following is the list of all the components that changed in 7.60 from 7.51. ******************************** cp006303.exe - HP ProLiant Integrated Management Log Viewer for Windows, v5.10.0.0 Enhancements Added new IML definitions to support new servers. Updated to support version 5.10.0.0 of the HP ProLiant Remote Monitor Service. This utility is not supported by version 5.2.2195.0 or earlier versions of the Remote Monitor Service. ******************************** cp006302.exe - HP ProLiant Remote Monitor Service for Windows, v5.10.0.0 Fixes Corrected the following: 1)Potential security vulnerability that allowed this service to pass arbitrary Device I/O Control requests to any device driver. 2)The service will no longer interact with the desktop. 3)Missing dependency on the Remote Procedure Call service. 4)Removed support for the following: a)HP ProLiant Integrated Management Display Utility b)HP ProLiant Enhanced Integrated Management Display Service c)HP ProLiant Power Down Manager d)HP ProLiant Power Supply Viewer ******************************** cp006260.exe - AMD Chipset Support for ProLiant Servers for Windows 2000/Windows Server 2003, v2.0.0.0 Enhancements Added support for the AMD-8132 HyperTransport IOAPIC Controller. Added support the for the HP ProLiant DL585 G2. ******************************** cp006284.exe - HP ProLiant iLO Advanced and Enhanced System Management Controller Driver for Windows 2000/Windows Server 2003, v5.41.0.0 Fixes Corrected the following: 1)An instance of WDM error 4200 when querying memory module information via WMI on the HP ProLiant BL45p 2)The display of the presence of fans 9 and 10 on the HP ProLiant DL585 when power supplies are removed 3)Missing overtemperature event entries in the Integrated Management Log and the Windows Event Log on the HP ProLiant DL585 ******************************** cp006403.exe - HP High Precision Event Timer NULL INF for Windows 2000/ Windows Server 2003, v1.0.0.0 Enhancements Initial release. ******************************** cp006269.exe - HP ProLiant CSB-6 ATA-100 IDE RAID Driver for Windows 2000/Windows Server 2003, v4.2.805.2005 Fixes 1) Added update to driver to program the task file registers properly. 2) Resolved an issue where the Sector count register was being programmed with an incorrect value. 3) Resolved an issue with error logging. ******************************** cp006261.exe - Intel Chipset Support for ProLiant Servers for Windows 2000/Windows Server 2003, v6.1.0.1008 C Enhancements Added support for eliminating the "yellow bang" on the high-precision event timer has been removed from this component, and is now provided by the HP High Precision Event Timer NULL INF component. ******************************** cp006262.exe - HP 6-Port SATA RAID Controller Driver for Windows 2000/Windows Server 2003, v4.2.1.7365 C Enhancements Modifications were made to the component installer to ensure driver files are copied to the correct locations. ******************************** cp006281.exe - HP Insight Management Agents for Windows 2000/Windows Server 2003, v7.60.0.0 Fixes The label "Redundancy Control" was updated to "Switchover Mode." Enhancements Added support for the following: 1) NC326m, NC325m, NC360T, and NC373T 2) cpqNicIfPhysAdapterSpeedMbps MIB item 3) Added SAS HBA tape support Optimized the algorithm to collect physical adapter information. Removed part-number for NC7170. Updated to report correct poll interval in cpqNicOsCommonPollFreq. NIC agent initialization error handling improved and number of retries increased. IP address of an interface will be displayed in SMH only if it is valid address. ******************************** cp006285.exe - HP Lights-Out Online Configuration Utility for Windows 2000/Windows Server 2003, v1.5.1.0 Fixes Updated to help customers to know if the management processor is not present, especially when the utility is used in scripts. The utility will return with a exit status of 2 when the management processor is not present. ******************************** cp006299.exe - HP ProLiant Smart Array SAS/SATA Controller Driver for Windows 2003, v5.10.0.32 Enhancements Added the following: 1) Enhancements to I/O path streaming to increase performance in all supported controllers. 2) SCSI Request Block (SRB) coalescing performance improvements for the Smart Array E200 and E200i controllers. ******************************** cp006265.exe - HP ProLiant Smart Array SAS/SATA Event Notification Service for Windows 2000/Windows Server 2003, v5.8.0.32 A Enhancements All fan and power supply/AC events have been changed to use 1 based numbering for location reporting in the Windows System Event Log. This is now in sync with hard drive bay numbering and how hard drives are reported. Additional functionality added to allow for the proper tracking of disabled devices for when the service is stopped. ******************************** cp006270.exe - HP ProLiant Storage System Driver for Windows 2000/Windows Server 2003, v5.22.0.32 B Fixes Fixed an installation/upgrade problem if the debug symbols for this driver are present on the system. ******************************** cp006263.exe - HP ProLiant Smart Array 5x and 6x Controller Driver for Windows 2000/Windows Server 2003, v5.72.0.32 B Fixes Smart Array 5x and 6x Notification Driver (cpqcisse.sys) Resolved an issue where CPQCISSE reported incorrect MSA20 box number when two MSA20's are connected. Enhancements Smart Array 5x and 6x Notification Driver (cpqcisse.sys) Updated Version Major Number for SmartStart 7.60. Smart Array 5x and 6x Controllers SCSI Miniport Driver (cpqcissm) Updated Version Major Number for Smart Start 7.60. ******************************** cp006304.exe - HP ProLiant Array Configuration Utility for Windows, v7.60.18.0 Enhancements Updated ACU Scripting with new features and capabilities ******************************** cp006305.exe - HP ProLiant Array Diagnostics Utility for Windows, v7.60.18.0 Fixes Resolved various report issues. ******************************** cp006306.exe - HP ProLiant Array Configuration Utility (CLI) for Windows, v7.60.19.0 Enhancements CLI now has two new show command parameters -> show [config] [detail]. See help for usage. ******************************** cp006282.exe - HP Insight Diagnostics Online Edition for Windows 2000/Windows Server 2003, v7.6.0.1984 Enhancements Added support for new ProLiant hardware. **************************************************************** cp006307.exe - HP Protect Your Data Information and Application Downloads for Windows, v1.0.2.0 Fixes This version includes minor bug fixes in installer translation and added warning to validate recommended solution against comatibility matrix and quick-spec. **************************************************************** cp006351.exe - HP NC31xx Fast Ethernet NIC Driver for Windows 2003, v8.0.27.0 Fixes This driver no longer enters adapter stop and start events into the event log, which reduces the size of the event log. **************************************************************** cp006352.exe - HP NC-Series Intel Driver for Windows 2003, v8.6.17.0 Enhancements This driver no longer limits the number of connected adapters to 32. The user can now connect more than 32 adapters. This driver no longer enters adapter stop and start events into the event log, which reduces the size of the event log. **************************************************************** cp006331.exe - HP Network Configuration Utility for Windows 2003, v8.40.00.0 Enhancements This software now: 1) Supports the NC360T and NC373T NICs. 2) Determines that the system has booted from an iSCSI target and prevents iSCSI from being disabled. 3) Allows teaming of TOE-enabled NICs for failover, redundancy, and load balancing of network connections. 4) Supports an update to Virus Throttle for the use of the Universal Datagram Packet protocol. The Virus Throttle feature requires a license for the HP ProLiant Intelligent Networking Pack. For more information about INP or to purchase a license, refer to www.hp.com/servers/networking. 5) Supports the Remote Memory Data Access (RDMA) feature for multifunction NICs. RDMA provides direct transmission of data from the memory of one computer to the memory of another with minimal demands on the host CPU. RDMA requires a license for the ProLiant Essentials RDMA Pack, which is available for standup and embedded NICs. For more information about ProLiant Essentials RDMA Pack or to purchase a license, refer to www.hp.com/servers/networking. **************************************************************** cp006641.exe - HP NC10xx/67xx/77xx/150x/320x/324x/325x/326x Gigabit Ethernet NIC Driver for Windows 2003, v9.52.0.0 Fixes This driver now links 5701 NICs at the correct speed after changing adapter properties. This driver no longer incorrectly shows the NC320x series of adapters to be down in a specific situation. The situation occurs when the NC320x device physically connects to a Cisco Catalyst 6500 switch, has the link speed and duplex property forced to 100mb FDX, and is continually rebooted. **************************************************************** cp006533.exe - HP NC-Series Multifunction Driver for Windows Server 2003, v2.8.15.0 Enhancements This driver now supports the NC373T. **************************************************************** cp006335.exe - HP Virus Throttle for Windows 2003, v8.40.00.0 Enhancements This driver now supports the NC360T and NC373T NICs. **************************************************************** cp006399.exe - HP NC-Series Intel N1E Driver for Windows 2003, v9.3.39.0 Enhancements Initial release. **************************************************************** cp006277.exe - HP ProLiant Integrated Lights-Out Management Interface Driver for Windows 2000/Windows Server 2003, v1.9.2195.0 Fixes Resolved issue related to physical memory allocation. **************************************************************** cp006280.exe - HP ProLiant Rack Infrastructure Interface Service for Windows 2000/Windows Server 2003, v1.22.0.0 B Fixes Updated the component to only install on p-Class blade servers. The Rack Infrastructure Interface Service is not needed on c-Class blades. **************************************************************** cp006258.exe - HP ProLiant iLO 2 Management Controller Driver for Windows 2000/Windows Server 2003, v1.1.0.0 Fixes Changed the installer DLL file name to prevent a mismatch with other files in the component package, causing the installer DLL to not be found. Updated the Automated Server Recovery(ASR) to function correctly after the iLO2 device is reset. Resolved an initialization issue with the driver when the iLO2 device with firmware version 1.11 is being flashed using a RIBCL flash. Resolved a potential blue screen that could occur when the iLO2 device is sharing interrupts with other devices. **************************************************************** cp006561.exe - HP NULL IPMI Controller Driver for Windows 2000/Windows Server 2003, v1.0.0.0 B Enhancements Updated the component installer to check and install only if the Microsoft Generic IPMI provider has not been installed. **************************************************************** cp006309.exe - HP System Management Homepage for Windows, v2.1.6.156 Enhancements Added "Back" button support to the User Interface. Addressed the following vulnerabilities: CVE-2005-3357: mod_ssl in Apache 2.0 up to 2.0.55, when configured with an SSL vhost with access control and a custom error 400 error page, allows remote attackers to cause a denial of service (application crash) via a non-SSL request to an SSL port, which triggers a NULL pointer dereference. CVE-2005-3352: Cross-site scripting (XSS) vulnerability in the mod_imap module of Apache httpd before 1.3.35-dev and Apache httpd 2.0.x before 2.0.56-dev allows remote attackers to inject arbitrary web script or HTML via the Referer when using image maps. **************************************************************** cp006308.exe - HP Version Control Agent for Windows, v2.1.5.760 Fixes Fixed saving/clearing Version Control Agent log with many entries. Enhancements Updated password re-verification for "Change Agent Settings". ******************************** cp006301.exe - HP 4/8 Internal Port SAS HBA with RAID Driver for Windows Server 2003, v1.21.17.00 Fixes Added SAS AEN notification when a SMART error is detected. ******************************** cp006240.exe - HP ProLiant IPMI Provider, v1.1.0.0 A Fixes Corrected the version number of IPMI Provider for installation using RDU. Resolved the uninstall issue so that the running state of other services dependent on the WMI service are the same before and after uninstalling the IPMI Provider. The solution is scripted so that the user will not be prompted about those services. ******************************** Copyright 2003-2006 Hewlett-Packard Development Company, L.P.