OSOTTM32 - ISSUES WITH PC320 SERVERS, NETFINITY TME 10, AND CERTAIN HARD DISK CONFIGURATIONS 10/17/96 ======================================================================= Issues with PC320 Servers, NetFinity TME 10, and Certain Hard disk Configurations ======================================================================= Please Read Entire Document for Full Explanation of Procedures -------------------------------------------------------------- DESCRIPTION Some hard disk models available for PC 320 Server series systems experience problems with TME 10 NetFinity and OS/2 Warp 4. By default, the TME 10 NetFinity icon is put in the startup folder. Intermittently, the PC 320 keyboard locks up when PMSHELL.EXE attempts to load the desktop, with the TME 10 Monitor application in the startup folder. RESOLUTION There are software workarounds for the problem: 1. Make sure that NetFinity (NETFBASE.EXE) is the last program to load, by either: In the Startup Folder, add WAIT:X to the Parameters field, (where X is a number of seconds) to the Netfinity Support Program icon, or, Remove the Netfinity Support Program icon from the Startup Folder, and add START NETFBASE.EXE to a STARTUP.CMD file Note: WAIT:X must be in capital letters; for example, WAIT:5. 2. Record the PC 320 Server model type and hard disk model and FRU number. Contact the IBM PC Company to determine whether engineering changes are required for your system. 3. If all of the following conditions apply to your system, there is a fix which can be obtained: - TME 10 Netfinity 4.0 or earlier is running on the Server. - The Server has an IBM PCI Fast/Wide Streaming RAID adapter (FRU p/n06H5078) or an IBM MicroChannel Fast/Wide Streaming adapter (FRU p/n92F0335 or FRU p/n06H3059). - The following hard drives are attached to the RAID adapter: 1GB FRU p/n06H8560 (Option p/n94G2649) 2GB FRU p/n06H8561 (Option p/n94G2650) (other HD models may be involved) Notes: 1. This fix is only for servers with TME 10 Netfinity V4.0. If the Server does not have TME 10 Netfinity V4.0, then it must first be upgraded to V4.0. 2. With a ServerGuide or a PC Server proof-of-purchase, you can obtain TME 10 Netfinity v4.0 by ordering ServerGuide version 2.51 from 1-800-426-7282. There is no charge if proof-of-purchase is provided. Follow this procedure: 1. Download TMEDDD.EXE from the IBM PC Company BBS. Expand the image onto a blank diskette using the command: TMEDDD A: 2. Upgrade to TME 10 Netfinity V4.0, if necessary. 3. Shutdown TME 10 Netfinity 4.0, by typing NETFBASE SHUTDOWN at an OS/2 command line. 4. Copy the appropriate operating system specific files from the TMEDDD.EXE diskette to the system's \NETFIN subdirectory. (Refer to the README files for instructions.) 5. Restart TME 10 Netfinity 4.0, by typing NETFBASE START at an OS/2 command line. Important: Review any "README" files located on the diskette for installation information. Contact the IBM PC HelpCenter at 800-772-2227 if download or installation assistance is needed. IBM TME 10 Netfinity files are located in Directory 40 on the IBM PC Company Bulletin Board Service (BBS) at: 1-919-517-0001. The files may also be downloaded via the Internet from the IBM PC File Library by searching the following Internet URL: http://www.pc.ibm.com/files.html If you have TME 10 Netfinity problems with PC servers, provide the versions of the software and hardware models affected. This will help resolve the issue and address potential hardware issues needing attention by the PC Company. warp4 ______________________________________________________________________ IBM disclaims all warranties, whether express or implied, including without limitation, warranties of fitness and merchantability with respect to the information in this document. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright (c) 1994, 1995 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult your product manuals for complete trademark information.