H125499: 3518 STORAGE ENCLOSURE: SYNCHRONIZATION MAY FAIL W/ 2.25 GB SYMPTOM: "Check Consistency" errors during synchronization of RAID 5 Logical drives, or Defunct (DDD) drives with any RAID level may be experienced. PROBLEM ISOLATION AIDS: All of the following must be true for this Tip to apply: - There are more than 6 x 2.25GB Hard Drives FRU p/n76H0958 (Option p/n's 07H0387 / 94G2650 / 70G9862) in a IBM 3518 External Storage Enclosure.with daisey-chained backplanes - The backplane (s) that these drives are connected to are daisey-chained. - The 3518 is attached to any RAID / ServeRAID / ServeRAID II Adapter / Controller in a IBM PC Server / Netfinity server. FIX: Connect each populated Backplane in the 3518 to a separate SCSI Channel. Refer to RETAIN TIP Record# H133777 for additional info on backplane jumper settings. Date: January 7, 1998