H162305: ECA015: PC SERVER 330 FIRMWARE UPGRADE ON SOME SELECT MO DELS PURPOSE: This ECA provides for the upgrade of Firmware code on the integrated ServeRAID II controller in the PC Server 330 type 8640 models PM0/PT0/PB0. This ECA is mandatory. Recent product evaluations have revealed that a data corruption condition can occur using the integrated ServeRAID II controller. Typical symptoms may include Operating System hangs, error executing a Operating System file, and in very rare occasions, corruption of data files could occur. Flashing the integrated ServeRAID II controller Firmware to rev. 97326 fixes the problem. This Firmware level is being implemented in manufacturing. FEATURES: Type, Machines Affected Model, With and/or Feature/Device B/M to be Service System Stage B/M Description Installed Hours Hours USA: 8640 B/M0000000 PC SERVER 330 TYPE B/M0000000 00.6 00.5 8640 MODEL PM0/PT0/PB0 EMEA: 8640 B/M0000000 PC SERVER 330 TYPE B/M0000000 00.8 00.8 8640 MODEL PM0/PT0/PB0 HOURS PER SYSTEM: 0.8 HOURS TRAVEL: 0.8. PHYSICAL CHECK: The following System Serial number ranges in the field are suspect of downlevel ServeRAID II controller Firmware: USA/WTTA: Increment example: 23YW998,23YW999,23YX000,23YX001 8640-PB0 23PR929 - 23PR999 23PT009 - 23PT394 23TN900 - 23TN999 23TP000 - 23TP999 23TR000 - 23TR999 23TT001 - 23TT999 23TV001 - 23TV999 23TW000 - 23TW899 23YT901 - 23YT999 23YV000 - 23YV721 23YW422 - 23YW999 23YX000 - 23YX431 8640-PT0 23PP935 - 23PP966 23PR142 - 23PR238 EMEA/FUJI: Increment example: 550736X,550736Y,550736Z,550737A 8640-PB0 555H21B - 555H47H 556F31P - 556H42B 550736X - 550894T 8640-PT0 555G940 - 555H21A 550578Z - 550707W 8640-PM0 555B31P - 555B84D 550421B - 550503A Shutdown the system, then reboot. Observe the Firmware level displayed when the integrated ServeRAID II controller BIOS loads. APPLY THIS ECA IF THE FIRMWARE LEVEL ON THE INTEGRATED SERVERAID II CONTROLLER IS 97239 OR LOWER. CHECK THE FIRMWARE LEVEL AND IF REQUIRED, APPLY THIS ECA IF REPLACING THE SYSTEM PLANER FRU P/N60H8109. PREREQUISITES: This condition is only possible when the integrated ServeRAID II controller is being used as a primary or secondary disk subsystem controller. However, the Firmware update is strongly recommended for all applicable systems whether the integrated ServeRAID II controller is currently being used or not. The integrated ServeRAID II controller is at Firmware level 97239 or lower. COMPANION: See the readme.txt file located on the "IBM PC Server 330 (8640-PB0, PM0, PT0) ServeRAID II Onboard Controller Firmware Update Diskette V2.31" for directions on the Firmware flash operation. CONCURRENT: NONE DETAIL: 1- Download the "IBM PC Server 330 (8640-PB0, PM0, PT0) ServeRAID II Onboard Controller Firmware Update Diskette V2.31" from the IBM Website URL: http://www.pc.ibm.com/us/files.html -Select SEARCH. -Type "ServeRAID II Firmware" in the Keywords box, then select SEARCH. -Select the File with the following description: "IBM PC Server 330 (8640-PB0, PM0, PT0) ServeRAID II Onboard Controller Firmware Update Diskette V2.31" The file is a self-extracting executable file that will create a diskette. 2- Print the readme.txt file located on the "IBM PC Server 330 (8640-PB0, PM0, PT0) ServeRAID II Onboard Controller Firmware Update Diskette V2.31" (using a workstation). 3- Shutdown, and power off the server. 4- Boot the Server with the "IBM PC Server 330 (8640-PB0, PM0, PT0) ServeRAID II Onboard Controller Firmware Update Diskette V2.31" and follow the directions in the readme.txt printout to apply the Firmware flash to the integrated ServeraRAID II controller. This Firmware flash will upgrade the integrated ServeRAID controller to rev. 97326. NOTES: This ECA will expire December 12, 1998. IBM/TSS CE's should record all time to Service Code 33, ECA015, other office 990. EMEA Dealers: Claim as type 5, referencing ECA015. Date: December 31, 1997