H166172: MULTI-SERVERAID: MISCELLANEOUS EVENTS OCCUR IN THE EVENT LOG SYMPTOM: Large number of soft and miscellaneous events occur in the ServeRAID soft event log and device event table. PROBLEM ISOLATION AIDS: - The system is any of the following IBM servers that support any one of the ServeRAID Adapters: a Netfinity 7000-M10 server, Type 8680, any Model. a Netfinity 7000 server, Type 8651, any Model. a Netfinity 5500-M20 server, Type 8662, any Model. a Netfinity 5500-M10 server, Type 8661, any Model. a Netfinity 5500 server, Type 8660, any Model. a Netfinity 5000 server, Type 8659, any Model. a Netfinity 3500 server, Type 8644, any Model. a Netfinity 3000 server, Type 8476, any Model. a Netfinity 704 server, Type 8650, any Model. a PC Server 720, Type 8642, any Model. a PC Server 520, Type 8641, any Model. a PC Server 330, Type 8640, any Model. a PC Server 325, Type 8639, any Model. a PC Server 320, Type 8640, any Model. a PC Server 315, Type 8638, any Model. a PC Server 310, Type 8639, any Model. Note: The Netfinity ServerProven Compatibility web page is at the following URL: http://www.pc.ibm.com/us/compat/ - The system is configured any combination of 2 of the following type of ServeRAID Adapters: ServeRAID Adapter FRU p/n06H9334 (Option p/n70G8489) ServeRAID Adapter FRU p/n76H6875 (Option p/n70G8489) ServeRAID II Adapter FRU p/n76H3587 (Option p/n76H3584) ServeRAID-3H Adapter FRU p/n01K7396 (Option p/n01K7207) ServeRAID-3L Adapter FRU p/n01K7352 (Option p/n01K7364) - The system is configured with ServeRAID Administration Utility (any version) with Logical Drive Migration (LDM) running and logical drive in critical state (1 DDD drive). - All firmware versions are affected for the ServeRAID Adapter. - NOS affected: Novell NetWare version 4.2 w/ IWSP6 applied. FIX: - This problem will be fixed in next BIOS/Firmware release. - It will be available from the following URL: http://www.pc.ibm.com/searchfiles.html search on "ServeRAID Firmware" WORKAROUND: - Do not run LDM with a DDD drive. - Reduce the amount of network activity during LDM. DETAILS: This problem may occur when the system's cache is highly utilized, a logical drive is in critical state (1 DDD drive) and 2 types of ServeRAID Adapters are installed. This problem has only been able to be replicated in development test when a drive goes DDD during an "add to free array space" LDM operation in NetWare v4.2 with IWSP6, a large amount of network activity, and two types of ServeRAID adapters installed in the system. Note: It may occur with other operating systems if the conditions regarding highly utilized cache with a critical logical drive are met, but development has not been able to replicate in any other operating system environment besides NetWare. TRADEMARKS: Other company, product and service names may be the trademarks or service marks of others. DATE: March 30, 1999